PART 1 GENERAL
1.1 SECTION INCLUDES A. Conservatories. B. Solariums. C. Skylights. D. Greenhouses. E. Hobby Greenhouses. F. Pool and Spa Enclosures. G. Walkways and Canopies. H. Accessories. I. Glass and glazing.
1.2 RELATED SECTIONS A. Section 03300 - Cast-In-Place Concrete: Cast-in-place concrete foundations and slabs. B. Section 07900 - Joint Sealers.
1.3 REFERENCES A. AAMA 611 - Voluntary Specification for Anodized Architectural Aluminum. B. ASTM A 36/A 36M - Standard Specification for Carbon Structural Steel. C. ASTM B 308/B 308M - Standard Specification for Aluminum-Alloy 6061-T6 Standard Structural Profiles. D. ASTM C 864 - Standard Specification for Dense Elastomeric Compression Seal Gaskets, Setting Blocks, and Spacers. E. AWS D1 - Structural Welding Code. F. FGMA - Flat Glass Marketing Association, Glazing Manual.
1.4 PERFORMANCE REQUIREMENTS A. Performance Requirements: Provide framing system supporting glazing, complete with all components necessary to provide a weathertight system, including perimeter flashing and sealants within the structure. 1. Provide structural design, engineering, and fabrication by manufacturer. 2. Design to withstand uniform structural load of 40 psf (195 kg/sq meter), or as required by code. 3. Design framing system and glazing material to support design loads as prescribed by the governing building code. 4. Design to withstand thermal variations of 60 degrees F (15.5 degrees C) from ambient temperature without causing bucking, stresses on glass, failure of seals, undue stress on structural elements, reduction of performance, or other detrimental effects. 5. Maximum Allowable Deflection of Any Framing Member Normal to Plane of Glazing: Not more than L/175. 6. No uncontrolled water leakage in system under normal circumstances.
1.5 SUBMITTALS A. Submit under provisions of Section 01300. B. Product Data: Manufacturer's data sheets on each product to be used, including: 1. Preparation instructions and recommendations. 2. Storage and handling requirements and recommendations. 3. Installation methods. C. Shop Drawings: Detailed drawings and structural calculations prepared specifically for the project by manufacturer provide stamp or seal of licensed professional engineer if required by authorities having jurisdiction. D. Selection Samples: Two complete sets of color chips representing manufacturer's full range of standard colors. E. Verification Samples: 1. Aluminum Finish: Two samples, minimum size 2 by 3 inches (50 by 75 mm), representing actual product and color. 2. Wood Finish: Two samples, minimum size 2 by 5 inches (50 by 127 mm), representing actual product and color. 3. Glass: Two samples, minimum size 12 inches (300 mm) square, of specified glass, including coatings or frit pattern. 4. Assembly Sample: 12 by 12 inch (300 by 300 mm) assembly complete with glazing, gaskets, fasteners, anchors, and finish do not proceed with fabrication until workmanship and color are approved by Architect. F. Manufacturer's Certificates: Certify products meet or exceed specified requirements.
1.6 QUALITY ASSURANCE A. Manufacturer Qualifications: Company specializing in manufacturing products specified in this Section with minimum 5 years experience in fabrication and erection of glazed structures for projects of similar scope. B. Installer Qualifications: Experienced in performing work of this section that has specialized in installation of work similar to that required for this project.
1.7 DELIVERY, STORAGE, AND HANDLING A. Store products in manufacturer's unopened packaging, covered to protect factory finishes from damage, precipitation, and construction dirt until ready for installation. B. Protect factory finishes from damage, precipitation and construction materials until ready for installation.
1.8 PROJECT CONDITIONS A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits. B. Perform structural silicone sealant work when air temperature is above 10 degrees F (minus 12 degrees C).
1.9 WARRANTY A. Provide glazed structure manufacturer's warranty that installed structure will be free from significant defects in material, workmanship, and uncontrolled water leakage for two years from date of Substantial Completion. (Reference original warranty for complete warranty time frames). B. Warranty anodized aluminum finish for five years. C. For stock color PPG Duranar 70 percent fluoropolymer finishes, provide paint manufacturer's warranty for color and film integrity for at least 10 years from date of application. D. For custom color PPG Duranar 70 percent fluoropolymer finishes, provide paint manufacturer's warranty for color and film integrity for at least ten years from date of application. E. For stock color PPG Acrynar 50 percent fluoropolymer finishes, provide warranty for color and film integrity for ten years from date of application. F. For custom color PPG Acrynar 50 percent fluoropolymer finishes, provide paint manufacturer's warranty for color and film integrity for at least ten years from date of application. G. For stock color PPG Duracron, thermosetting acrylic resin finishes, provide warranty for cracking and pulling integrity for five years from date of application. H. For custom color PPG Duracron, thermosetting acrylic resin finishes, provide paint manufacturer's warranty for cracking and pulling integrity for at least five years from date of application. I. For glazing, provide glazing manufacturer's standard warranty against defective materials, de-lamination, seal failure, and defects in manufacturing for up to fifteen (15) years prorated or as otherwise provided in or limited by the Glass manufacturer's limited warranty.
PART 2 PRODUCTS
2.1 GLAZED STRUCTURES A. Conservatory: 1. Framing Members: Aluminum. 2. Framing Members: Solid wood interior, aluminum exterior aluminum base plate and pressure cap system. 3. Glazing: 1/8 inch (3 mm) float glass. 4. Glazing: 3/16 inch (5 mm) float glass. 5. Glazing: 1/4 inch (7 mm) float glass. 6. Glazing: 1 inch (25 mm) sealed insulating glass. 7. Glazing: ___________. 8. Framing Member Cross Section: 2 by 2-13/16 inches (50 by 71 mm) not including glazing depth. 9. Framing Member Cross Section: 2 by 5-1/2 inches (50 by 140 mm) not including glazing depth. 10. Framing Member Cross Section: As required to accomplish performance criteria. 11. Framing Member Cross Section: ___________. 12. Accessories: a. Corners. b. Corner posts. c. Ridge crests. d. Moldings. e. Decorative crown. f. Decorative gutter. g. Finials. h. Transom band. 13. Dimensions: a. Ridge Height: ________. b. Eave Height: ________. c. Roof Pitch: ________. d. Projection: ________. e. Width: ________. f. Length: ________. 14. Basic Mullion and Purlin Design: Uniform bay widths dimension as recommended by manufacturer. 15. Basic Mullion and Purlin Design: As indicated on the Drawings. 16. Local Code Jurisdiction: ________. B. Solarium/Sunroom: 1. Framing Members: Aluminum. 2. Framing Members: Solid wood interior, aluminum exterior aluminum base plate and pressure cap system. 3. Configuration: Straight eave. 4. Configuration: Curved eave. 5. Glazing: 1/8 inch (3 mm) float glass. 6. Glazing: 3/16 inch (5 mm) float glass. 7. Glazing: 1/4 inch (7 mm) float glass. 8. Glazing: 1 inch (25 mm) sealed insulating glass. 9. Glazing: ___________. 10. Framing Member Cross Section: 2 by 2-13/16 inches (50 by 71 mm) not including glazing depth. 11. Framing Member Cross Section: 2 by 5-1/2 inches (50 by 140 mm) not including glazing depth. 12. Framing Member Cross Section: As required to accomplish performance criteria. 13. Framing Member Cross Section: _____.